An air conditioner, heat pump or furnace that keeps tripping its breaker has an electrical fault somewhere between the panel and the motors inside the equipment. The usual suspects are a compressor that struggles to start, a failing capacitor or fan motor, a short in the wiring, or a circuit that carries more than it should. When the breaker trips is the most useful clue to which one, so pay attention to the timing before you call.
First: smoke, sparks or a burning smell
If the breaker tripped with a bang, or you see smoke, sparks or scorch marks at the electrical panel, the disconnect box beside the outdoor unit or the furnace, don’t reset anything. Get everyone out and call 911 from outside. If there’s no smoke but a hot electrical smell hangs around the equipment, keep the breaker off and call for emergency HVAC service.
Reset it once, the right way
- Set the thermostat to OFF so the system doesn’t try to start the moment power returns.
- Find the tripped breaker. It usually sits in the middle position or leans toward OFF. Push it firmly all the way to OFF, then back to ON.
- Wait several minutes before asking for cooling or heat. An AC or heat pump compressor starts more easily once the refrigerant pressures have evened out, and many thermostats build in this delay anyway.
- Turn the system on and stay close for the first few minutes. At the outdoor unit, listen for a hum or buzz with the fan not turning, or a hard clunk.
If it trips again, that’s your answer. Leave it off and call. Don’t hold the handle in the ON position, don’t tape it, and don’t swap in a larger breaker.
What the timing tells you
| When it trips | What it usually points to | Typical fix |
|---|---|---|
| The instant you reset it, with the thermostat off | A short or ground fault in wiring, a motor or the compressor | Find and repair the fault; a shorted compressor may mean replacement |
| A second or two after the outdoor unit tries to start | A hard-starting compressor, a failed capacitor, a sticking contactor | Capacitor or contactor replacement, sometimes a start assist |
| After the system has run for a while | An overload: dirty outdoor coil, failing condenser fan motor, a blower motor with worn bearings | Coil cleaning, motor replacement |
| Only when backup heat comes on | Heat strip element, relay or connection | Heat strip and wiring repair |
| Only when other appliances are running | A shared or overloaded circuit | A dedicated circuit, work for an electrician |
| At random, with no pattern | A worn breaker or a loose, heat-damaged connection | Tightening or replacing the part |
Why compressors are so often behind it
The compressor is the biggest electrical load in most homes with central AC or a heat pump. It needs a burst of current to start, helped by a capacitor. Capacitors weaken with heat and age, and as they do the compressor takes longer to get going, draws more current while it tries, and finally trips the breaker. Over many years a compressor’s internal windings can also break down and short to its metal shell. That trips the breaker immediately and usually can’t be repaired. It’s the point where we compare a new compressor with replacing the outdoor unit or the whole system, depending on its age, its refrigerant and the condition of everything else. AC compressor not working covers those signs in more detail.
Furnaces and air handlers
A gas furnace draws far less current than an air conditioner, so one that trips a breaker usually has a specific problem: a blower or inducer motor that is binding, a short in the wiring or the control board, or a circuit it shares with other loads. Electric furnaces and air handlers with heat strips draw much more, and they trip from burned elements and connections that have overheated over time. On a heat pump that trips only during heating, see heat pump not working.
The first hot week of the year
In Santa Rosa, Rohnert Park, Cotati and Petaluma, many central air conditioners sit almost idle through the cool months and then face a heat wave. A compressor that started fine in spring has to start against much higher pressure on a hot afternoon, and that is when a weak capacitor or a tired compressor gives itself away. Older homes where AC was added years after the house was built can also have it on a circuit or panel that was never planned for it.
What we check
We start with the power off, and test before replacing anything: insulation resistance on the compressor and motor windings, the capacitor against its rating, the contactor, and every connection from the panel through the disconnect to the unit. Then we measure running current against the nameplate and confirm the breaker and wire size match what the equipment calls for. You get the cause, the fix and the price before work begins. If the real problem is the panel or the circuit, we tell you it’s a job for an electrician rather than selling an HVAC part that won’t solve it.